Conie Const., Inc. v. Reich, 94-1592

Decision Date30 October 1995
Docket NumberNo. 94-1592,94-1592
Citation73 F.3d 382
Parties, 17 O.S.H. Cas. (BNA) 1488, 1996 O.S.H.D. (CCH) P 31,003 CONIE CONSTRUCTION, INC., Petitioner, v. Robert B. REICH, Secretary of Labor, and the Occupational Safety and Health Review Commission, Respondents.
CourtU.S. Court of Appeals — District of Columbia Circuit

Roger L. Sabo, Columbus, OH, argued the cause for petitioner.

Bruce Justh, Counsel, Department of Labor, argued the cause for respondent. Joseph M. Woodward, Associate Solicitor, and Barbara U. Werthmann, Counsel, Department of Labor, Washington, DC, were on the brief.

Before: BUCKLEY, WILLIAMS and HENDERSON, Circuit Judges.

Opinion for the court filed PER CURIAM.

PER CURIAM:

Conie Construction, Incorporated (Conie) petitions the Court to review and set aside an order of the Occupational Safety and Health Review Commission (Commission) upholding a citation issued by the Occupational Safety and Health Administration (OSHA). The Commission found that Conie willfully violated OSHA's regulations by inadequately sloping the walls of a trench and assessed a penalty of $21,000. We deny Conie's petition.

I.

On November 6, 1991 Conie dug a trench to install a sewer manhole. That same day, an OSHA compliance officer inspected Conie's trench, took some measurements and concluded that the walls were sloped too steeply. The compliance officer was informed that Conie employees had worked in the trench that day.

Conie received a citation from OSHA alleging a violation of 29 C.F.R. Sec. 1926.652(a)(1), which requires employers to implement an adequate protective system for employees working in excavations. In particular, the citation alleged that Conie willfully failed to slope its trench in accordance with the applicable OSHA sloping standard as required by 29 C.F.R. Sec. 1926.652(b). OSHA proposed a penalty of $21,000.

Conie contested the citation and a hearing was held before an administrative law judge (ALJ). The compliance officer testified that he had measured the trench to be 20 feet by 24 feet at the top and 21 feet deep and had estimated the bottom to be 4 feet wide. He further testified that Conie's foreman, Russell Kildarger, acknowledged that the walls were not sloped according to OSHA's regulations but that Kildarger believed the trench was safe nevertheless. Finally, he testified that in the past three years OSHA had twice before cited Conie for inadequately protecting the walls of excavations.

Several witnesses testified for Conie. A soils engineer opined that the soil in the trench was firm enough to allow the walls to be sloped safely at a ratio of 1/2:1 (that is, 1/2 foot horizontal to 1 foot vertical, or a 63? angle). Foreman Kildarger testified, among other things, that he was familiar with OSHA's regulations, that he used a slope of 1/2:1 because he thought that would be safe and that the top of the trench "was about 22 foot wide." Joint Appendix (JA) 176. Joseph Conie, the company's co-owner and safety director, testified that he was familiar with OSHA's standards and that he "couldn't see anything wrong with the trench there." JA 244.

The ALJ ruled in Conie's favor and vacated the citation. The ALJ observed that, because the trench walls were dug in Type A soil (the most stable type of soil), OSHA's regulations allowed a maximum slope of 3/4:1 (53? angle). See 29 C.F.R. Sec. 1926.652(b)(2) and Subpart P, App. B, Table B-1.1 (maximum allowable slope in excavation less than 20 feet deep in Type A soil "shall be" 3/4:1). The ALJ found that the Secretary of Labor (Secretary) failed to show by a preponderance of the evidence that Conie did not meet that standard.

The Commission reversed the ALJ's decision after finding that Conie willfully failed to use a slope of 3/4:1 and assessed the Secretary's recommended penalty of $21,000. Conie appeals.

II.
A.

Conie first challenges the Commission's finding of a violation. Specifically, Conie contends that the record does not support the finding that the walls of its trench were sloped steeper than 3/4:1. The Commission's finding is conclusive if it is supported by substantial evidence on the record. 29 U.S.C. Sec. 660(a).

If Conie had used a slope of 3/4:1, the top of its trench would have measured at least 26 1/2 feet across. 1 The Commission found that the top of the trench measured less than 26 1/2 feet across. It referred to Kildarger's testimony that the trench was "about 22 foot wide" at the top. Conie urges that Kildarger was only estimating. But the Commission also referred (in an accompanying footnote) to the compliance officer's testimony that Kildarger was aware the trench had not been sloped in compliance with OSHA's standards. The Commission also noted that the compliance officer had measured the top of the trench to be 20 feet by 24 feet. In short, substantial evidence supports the Commission's finding that Conie violated the applicable OSHA sloping standard.

Conie nevertheless argues that the Commission took too formalistic a view of OSHA's regulations and that a 3/4:1 slope would have been sufficient, but not necessary, to comply with the regulations. Conie asserts that the maximum allowable slopes set out in Appendix B to Subpart P of OSHA's regulations are not mandatory, that the regulations are "performance oriented" and that the crucial question is whether the employer has put in place an "adequate protective system."

The short answer is that the regulations are performance oriented only insofar as they allow the employer to use alternative methods of protection in certain circumstances. See generally 29 C.F.R. Sec. 1926.652(b), (c). For example, instead of relying on the maximum allowable slopes set forth in Appendix B, Conie could have used an alternative support system, e.g., id. Sec. 1926.652(c) (shield system), or a steeper slope if designed by a registered professional engineer, id. Sec. 1926.652(b)(4). But Conie did not use any alternative method and instead chose to rely on the sloping standards set out in Appendix B. Consequently, the regulations plainly required Conie to use a maximum slope of 3/4:1. See id. Sec. 1926.652(b)(2) (maximum allowable slopes "shall be determined in accordance with the conditions and requirements set forth in appendices A and B"; Appendix B in turn provides that "[a]ll simple slope excavation 20 feet or less in depth shall have a maximum allowable slope of 3/4:1") (emphasis added).

B.

Conie next challenges the Commission's finding of a willful violation. The Occupational Safety and Health Act of 1970 (Act) provides an enhanced civil penalty for willful violations of the Act. 29 U.S.C. Sec. 666(a). "Although the Act does not define the term 'willful,' courts have unanimously held that a willful violation of the Act constitutes an act done voluntarily with either an intentional disregard of, or plain indifference to, the Act's requirements." Ensign-Bickford Co. v. OSHRC, 717 F.2d 1419, 1422 (D.C.Cir.1983) (internal quotation marks omitted), cert. denied, 466 U.S. 937, 104 S.Ct. 1909, 80 L.Ed.2d 458 (1984). Here, the Commission found that Conie's violation was willful largely because Conie was aware of OSHA's excavation requirements but chose not to comply with them. Substantial evidence supports the finding. Foreman Kildarger testified he was aware of the sloping standard (allowing a maximum slope of 3/4:1) but opted for a slope of 1/2:1 because he thought it adequate. And the compliance officer testified that Kildarger acknowledged the walls were not sloped in accordance with OSHA's regulations but that he (Kildarger) believed the trench was nonetheless safe.

C.

Conie next challenges the Commission's penalty. In assessing a civil penalty the Commission must consider "the size of the [employer's] business ..., the gravity of the violation, the good faith of the employer, and the history of previous violations." 29 U.S.C. Sec. 666(j). The Commission imposed the Secretary's proposed $21,000 penalty (30 per cent of the statutory maximum for a willful violation) after concluding that the gravity of Conie's...

To continue reading

Request your trial
8 cases
  • P. Gioioso & Sons, Inc. v. Occupational Safety and Health Review Com'n
    • United States
    • U.S. Court of Appeals — First Circuit
    • 13 Junio 1997
    ...acceptable procedures, not to jury-rig convenient alternatives and impose them on an imperilled work force. See Conie Constr., Inc. v. Reich, 73 F.3d 382, 384 (D.C.Cir.1995). We have said enough on this score. Because the excavation regulation applies to the trench in question whereas the d......
  • Kaspar Wire Works v. Secretary of Labor
    • United States
    • U.S. Court of Appeals — District of Columbia Circuit
    • 6 Noviembre 2001
    ...done voluntarily with either an intentional disregard of, or plain indifference to, the Act's requirements." Conie Construction, Inc. v. Reich, 73 F.3d 382, 384 (D.C. Cir. 1995). The Commission relied on the Fifth Circuit's virtually identical definition of a "willful violation" as "one inv......
  • American Wrecking Corp. v. Secretary of Labor
    • United States
    • U.S. Court of Appeals — District of Columbia Circuit
    • 19 Diciembre 2003
    ...could have known of the violative condition." Conie Constr., Inc., 16 O.S.H. Cas. (BNA) 1870, at *1 (O.S.H.R.C.1994), aff'd, 73 F.3d 382 (D.C.Cir.1995). Employers may seek discretionary review of adverse decisions before the Commission and, in turn, may petition the court of appeals for jud......
  • Frank Lill & Son, Inc. v. Secretary of Labor
    • United States
    • U.S. Court of Appeals — District of Columbia Circuit
    • 6 Abril 2004
    ...(D.C.Cir.2002) (quoting Kaspar Wire Works, Inc. v. Sec'y of Labor, 268 F.3d 1123, 1127 (D.C.Cir.2001) (quoting Conie Constr., Inc. v. Reich, 73 F.3d 382, 384 (D.C.Cir.1995))). 4. Lill does not dispute that the nature of the violation satisfies the statutory requirements of a serious violati......
  • Request a trial to view additional results

VLEX uses login cookies to provide you with a better browsing experience. If you click on 'Accept' or continue browsing this site we consider that you accept our cookie policy. ACCEPT