United Fire & Cas. Co. v. Whirlpool Corp., 11–15011.

CourtUnited States Courts of Appeals. United States Court of Appeals (11th Circuit)
Citation704 F.3d 1338
Docket NumberNo. 11–15011.,11–15011.
PartiesUNITED FIRE AND CASUALTY COMPANY, a.s.o. Robert and Theresa Corral, Plaintiff–Appellant, v. WHIRLPOOL CORPORATION, a Delaware corporation, Defendant–Appellee.
Decision Date17 January 2013

704 F.3d 1338

UNITED FIRE AND CASUALTY COMPANY, a.s.o. Robert and Theresa Corral, Plaintiff–Appellant,
v.
WHIRLPOOL CORPORATION, a Delaware corporation, Defendant–Appellee.

No. 11–15011.

United States Court of Appeals,
Eleventh Circuit.

Jan. 17, 2013.


[704 F.3d 1339]


Carol M. Rooney, Hobart M. Hind, Jr., Butler, Pappas, Weihmuller, Katz, Craig, LLP, Tampa, FL, for Plaintiff–Appellant.

David R. Pruitt, Tracy David Knox, Barnes & Thornburg, LLP, South Bend, IN, Bill B. McEachern, Jr., Moulton, McEachern & Walker, PA, Pensacola, FL, for Defendant–Appellee.


Appeal from the United States District Court for the Northern District of Florida.
Before BARKETT and JORDAN, Circuit Judges, and SCHLESINGER,1 District Judge.

PER CURIAM:

United Fire and Casualty Company (“United Fire”) appeals district court orders excluding the proffered testimony of two expert witnesses and granting Whirlpool Corporation's (“Whirlpool”) motion for summary judgment on United Fire's sole claim of relief. United Fire, as subrogee for Robert and Theresa Corral (the “Corrals”), brought a strict products liability suit against Whirlpool, alleging that a Whirlpool-manufactured clothes dryer caused a June 2008 fire in the Corrals' home. On appeal, United Fire argues that the district court abused its discretion in finding testimony of its two expert witnesses unreliable on the grounds that the experts did not perform testing of exemplars and because their theories regarding the origin of the fire had not been published. Even if the experts were properly excluded, United Fire contends that the district court erred in granting Whirlpool's motion for summary judgment on its product liability claim as material facts surrounding the cause and origin of the fire were in dispute. After reviewing the proposed testimony of United Fire's expert witnesses, we conclude that the district court abused its discretion in categorically excluding all of the expert witnesses' testimony. As those experts' testimony creates a dispute as to a material fact about whether the fire started as a result of the operation of the Whirlpool dryer, we also reverse the district court's grant of Whirlpool's motion for summary judgment.

I. Background

At 9:57 pm on June 20, 2008, the Jackson County Fire Department received a report of a fire in the home of the Corral family. Details about how and when the fire began are sparse because the Corral family had gone out for the evening and nobody was home. However, shortly before

[704 F.3d 1340]

leaving for dinner, at around 8:00 pm, one of the Corral children placed a load of laundry in the family's Whirlpool dryer and turned on the dryer.

Preliminary investigations by the Jackson County Fire Department suggested that the fire originated in the utility room where the Whirlpool dryer was located. United Fire retained Raymond Arms, a professional engineer and certified Fire and Explosives investigator, to investigate the cause and origin of the fire at the Corral residence. Mr. Arms investigated the scene of the fire using a systemic approach in accordance with the National Fire Protection Association's “NFPA 921” guide for fire and explosion investigations. Mr. Arms noted that the utility room in which the dryer was located was the most burned part of the house and concluded that the burn patterns within the utility room indicated that the dryer was at the center of the fire's origin. Further investigation revealed that the wall behind the dryer was totally consumed and that the wiring in that wall showed evidence of melting. Mr. Arms also observed that a piece of linoleum floor had burned and stuck to the bottom of the dryer. No other part of the floor of the utility room showed similar patterns of burning, including the floor near and underneath the washing machine. Based on these observations, Mr. Arms concluded that the fire originated with the dryer. He ruled out the possibility that the fire started outside of the dryer because an external fire would not have burned the linoleum under the dryer in the manner that was observed at the fire scene.

Mr. Arms then removed the dryer from the fire scene to conduct a destructive examination of the dryer, which occurred on September 24, 2008 in the presence of Whirlpool's expert witness. At this examination, the dryer was systematically deconstructed and inspected. At the end of the examination, Mr. Arms discovered a wire sticking to the exhaust tube on the bottom of the dryer. Examining the wire and noting that its insulation had worn thin, Mr. Arms concluded that the wire was the likely source of the ignition of the fire. He determined that the wire faulted with the metal tube enabling electricity to flow through the resistance between the wire and the tube. This flow of electricity, combined with the operation of the dryer's fan blowing air over the area of the fault, generated enough heat to ignite venting on the outside of the dryer. Mr. Arms did not test any exemplars to evaluate the plausibility of his ignition theory. He could not point to any published studies documenting this ignition sequence and he had never seen this ignition sequence occur before in his professional experience.

Following the destructive examination of the dryer, United Fire retained Dr. Kendall Clarke to examine the metal exhaust tube in the base of the dryer, which Mr. Arms had identified as the likely source of the electrical fault which ignited the fire. Dr. Clarke, a professional engineer with a doctorate in fracture mechanics, examined the steel tube using metallurgic imaging equipment, including a low-power microscope and an electron microscope. On one sample from the tube, he found columnar grains that suggested that part of the metal tube had melted. Dr. Clarke noted that to melt the type of the low-carbon steel used in the metal tube required a temperature of at least 2800 degrees combined with a forced draft. Dr. Clarke surmised that the fan in the dryer must have been the source of such a draft as there was no other source of a forced draft within the dryer.

II. Exclusion of United Fire's Experts

We turn first to the district court's decision to exclude the testimony of

[704 F.3d 1341]

United Fire's two experts on the basis that neither expert's testimony was grounded in a reliable methodology. We review decisions about the admissibility of an expert's testimony on an abuse of discretion standard. Rink v. Cheminova, Inc., 400 F.3d 1286...

To continue reading

Request your trial
62 cases
  • Med. Ctr., Inc. v. Bowden, A18A1249
    • United States
    • United States Court of Appeals (Georgia)
    • November 1, 2018
    ...is not an exhaustive list of factors, and courts may consider them in a "flexible" manner. United Fire & Cas. Co. v. Whirlpool Corp. , 704 F.3d 1338, 1341 (II) (11th Cir. 2013). The trial court may not exclude an otherwise sufficient expert opinion "simply because it believes that the opini......
  • Carrizosa v. Chiquita Brands Int'l, Inc., 19-13926
    • United States
    • United States Courts of Appeals. United States Court of Appeals (11th Circuit)
    • September 6, 2022
    ...on which Mr. Kaplan relied, the court abused its discretion in excluding his opinion. See United Fire & Cas. Co. v. Whirlpool Corp. , 704 F.3d 1338, 1341–42 (11th Cir. 2013) (reversing the exclusion of a portion of an expert's testimony because the district court had failed to consider the ......
  • Water v. HDR Eng'g, Inc., 12–14600.
    • United States
    • United States Courts of Appeals. United States Court of Appeals (11th Circuit)
    • September 23, 2013
    ...and (4) whether the technique has been generally accepted in the relevant scientific community.United Fire & Cas. Co. v. Whirlpool Corp., 704 F.3d 1338, 1341 (11th Cir.2013) (per curiam) (citing Daubert, 509 U.S. at 593–94, 113 S.Ct. 2786). “At the same time, the Court has emphasized that t......
  • Cash v. LG Elecs., Inc., A17A0878.
    • United States
    • United States Court of Appeals (Georgia)
    • September 8, 2017
    ...is not an exhaustive list of factors, and courts may consider them in a "flexible" manner. United Fire & Cas. Co. v. Whirlpool Corp. , 704 F.3d 1338, 1341 (II) (11th Cir. 2013). The trial court may not exclude an otherwise sufficient expert "simply because it believes that the opinion is no......
  • Request a trial to view additional results

VLEX uses login cookies to provide you with a better browsing experience. If you click on 'Accept' or continue browsing this site we consider that you accept our cookie policy. ACCEPT